  "legislation_title": "Council Decision of 13 November 2012 on the signing and conclusion of the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment (Text with EEA relevance) (2013/107/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2013-107",
  "path": "schedule/ANNEX C/division/III./division/D./division/3./division/(d)",
  "kind": "division",
  "number": "(d)",
  "heading": "Measurement Procedure",
  "text": "To measure time, an ordinary stopwatch and timing to a resolution of one second is sufficient. All power figures are to be recorded in watts (W). Table 9 outlines the steps of the OM test procedure.\nService/maintenance modes (including colour calibration) generally should not be included in measurements. Any adaptation of the procedure needed to exclude such modes that occur during the test must be noted.\nAs stated above, all power measurements are to be made in accordance with IEC 62301. Depending on the nature of the mode, IEC 62301 provides for instantaneous power measurements, five-minute accumulated energy measurements, or accumulated energy measurements over periods long enough to properly assess cyclical consumption patterns. Regardless of the method, only power values should be reported.\nTable 9\nOM Test Procedure\nStep\nInitial State\nAction\nRecord\n1\nOff\nPlug the unit into meter. Turn on unit. Wait until unit indicates it is in Ready mode.\n—\n2\nReady\nPrint, copy, or scan a single image.\n—\n3\nReady\nMeasure Ready power.\nReady power\n4\nReady\nWait default delay time to Sleep.\nSleep default delay time\n5\nSleep\nMeasure Sleep power.\nSleep power\n6\nSleep\nWait default delay time to Auto-off.\nAuto-off default delay time\n7\nAuto-off\nMeasure Auto-off power.\nAuto-off power\n8\nOff\nManually turn device off. Wait until unit is off.\n—\n9\nOff\nMeasure Off power.\nOff power",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2013/107/schedule/ANNEX C/division/III./division/D./division/3./division/(d)",
    "retrieved_at": "2026-11-01T15:15:09.798475+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}